| Description | | -30°C | -25°C | -20°C | -15°C | -10°C | -5°C | 0°C | +5°C |
|---|
| 25°C | Capacity | 3859 | 5684 | 7835 | 10349 | 13266 | 16624 | 20460 | 24814 | 29723 |
| Power | 2279 | 2480 | 2586 | 2627 | 2632 | 2630 | 2651 | 2724 | 2877 |
| Current | 4.2 | 4.7 | 5.1 | 5.4 | 5.6 | 5.9 | 6.1 | 6.3 | 6.6 |
| MassFlow | 72.5 | 105.0 | 142.3 | 185.1 | 233.9 | 289.2 | 351.5 | 421.4 | 499.4 |
| COP | 1.69 | 2.29 | 3.03 | 3.94 | 5.04 | 6.32 | 7.72 | 9.11 | 10.33 |
| Efficiency | | | | | | | | | |
| | | | | | | | | | |
| 30°C | Capacity | 3513 | 5184 | 7171 | 9513 | 12249 | 15416 | 19053 | 23199 | 27892 |
| Power | 2392 | 2721 | 2943 | 3087 | 3182 | 3258 | 3344 | 3468 | 3661 |
| Current | 4.3 | 4.9 | 5.4 | 5.8 | 6.1 | 6.4 | 6.6 | 6.9 | 7.2 |
| MassFlow | 69.6 | 101.0 | 137.4 | 179.4 | 227.4 | 282.0 | 343.7 | 413.1 | 490.6 |
| COP | 1.47 | 1.91 | 2.44 | 3.08 | 3.85 | 4.73 | 5.70 | 6.69 | 7.62 |
| Efficiency | | | | | | | | | |
| | | | | | | | | | |
| 35°C | Capacity | 3199 | 4723 | 6555 | 8733 | 11295 | 14281 | 17727 | 21673 | 26158 |
| Power | 2345 | 2803 | 3141 | 3388 | 3575 | 3728 | 3879 | 4056 | 4289 |
| Current | 4.2 | 5.0 | 5.6 | 6.1 | 6.5 | 6.8 | 7.1 | 7.4 | 7.8 |
| MassFlow | 65.2 | 95.7 | 131.2 | 172.3 | 219.6 | 273.6 | 334.7 | 403.5 | 480.7 |
| COP | 1.36 | 1.69 | 2.09 | 2.58 | 3.16 | 3.83 | 4.57 | 5.34 | 6.10 |
| Efficiency | | | | | | | | | |
| | | | | | | | | | |
| 40°C | Capacity | 2910 | 4296 | 5981 | 8003 | 10400 | 13212 | 16476 | 20231 | 24515 |
| Power | 2168 | 2756 | 3210 | 3562 | 3839 | 4071 | 4287 | 4517 | 4789 |
| Current | 4.0 | 5.0 | 5.7 | 6.3 | 6.8 | 7.2 | 7.6 | 7.9 | 8.4 |
| MassFlow | 59.6 | 89.2 | 123.9 | 164.3 | 210.9 | 264.2 | 324.8 | 393.2 | 469.9 |
| COP | 1.34 | 1.56 | 1.86 | 2.25 | 2.71 | 3.25 | 3.84 | 4.48 | 5.12 |
| Efficiency | | | | | | | | | |
| | | | | | | | | | |
| 45°C | Capacity | | 3897 | 5443 | 7317 | 9558 | 12204 | 15294 | 18866 | 22958 |
| Power | | 2609 | 3181 | 3636 | 4005 | 4316 | 4598 | 4880 | 5193 |
| Current | | 4.8 | 5.7 | 6.4 | 7.0 | 7.5 | 8.0 | 8.4 | 8.9 |
| MassFlow | | 81.9 | 115.8 | 155.5 | 201.5 | 254.2 | 314.3 | 382.3 | 458.7 |
| COP | | 1.49 | 1.71 | 2.01 | 2.39 | 2.83 | 3.33 | 3.87 | 4.42 |
| Efficiency | | | | | | | | | |
| | | | | | | | | | |
| 50°C | Capacity | | | 4936 | 6671 | 8764 | 11253 | 14176 | 17573 | 21482 |
| Power | | | 3082 | 3642 | 4102 | 4492 | 4840 | 5176 | 5529 |
| Current | | | 5.6 | 6.5 | 7.2 | 7.8 | 8.4 | 8.9 | 9.5 |
| MassFlow | | | 107.3 | 146.3 | 191.7 | 243.9 | 303.6 | 371.3 | 447.4 |
| COP | | | 1.60 | 1.83 | 2.14 | 2.51 | 2.93 | 3.40 | 3.89 |
| Efficiency | | | | | | | | | |
| | | | | | | | | | |
| 55°C | Capacity | | | | 6059 | 8011 | 10351 | 13117 | 16348 | 20081 |
| Power | | | | 3608 | 4160 | 4629 | 5044 | 5434 | 5828 |
| Current | | | | 6.5 | 7.3 | 8.1 | 8.8 | 9.4 | 10.0 |
| MassFlow | | | | 137.0 | 181.8 | 233.6 | 292.9 | 360.2 | 436.1 |
| COP | | | | 1.68 | 1.93 | 2.24 | 2.60 | 3.01 | 3.45 |
| Efficiency | | | | | | | | | |
| | | | | | | | | | |
| 60°C | Capacity | | | | | 7295 | 9495 | 12111 | 15183 | 18749 |
| Power | | | | | 4210 | 4758 | 5240 | 5684 | 6119 |
| Current | | | | | 7.4 | 8.3 | 9.2 | 9.9 | 10.6 |
| MassFlow | | | | | 172.3 | 223.6 | 282.6 | 349.6 | 425.3 |
| COP | | | | | 1.73 | 2.00 | 2.31 | 2.67 | 3.06 |
| Efficiency | | | | | | | | | |
| | | | | | | | | | |
| 65°C | Capacity | | | | | 6611 | 8678 | 11153 | 14075 | 17482 |
| Power | | | | | 4280 | 4908 | 5457 | 5955 | 6433 |
| Current | | | | | 7.5 | 8.6 | 9.5 | 10.4 | 11.3 |
| MassFlow | | | | | 163.2 | 214.2 | 272.9 | 339.7 | 415.3 |
| COP | | | | | 1.54 | 1.77 | 2.04 | 2.36 | 2.72 |