Производители

Описание
| Description | | -30°C | -25°C | -20°C | -15°C | -10°C | -5°C | 0°C | +5°C |
|---|
| 25°C | Capacity | 3740 | 4781 | 6532 | 8941 | 11955 | 15523 | 19593 | 24113 | 29032 |
| Power | 2056 | 2172 | 2391 | 2661 | 2931 | 3150 | 3267 | 3230 | 2989 |
| Current | 4.3 | 4.4 | 4.7 | 5.1 | 5.4 | 5.7 | 5.8 | 5.8 | 5.4 |
| MassFlow | 84.4 | 79.0 | 116.7 | 191.6 | 297.6 | 429.0 | 579.7 | 743.8 | 915.5 |
| COP | 1.82 | 2.20 | 2.73 | 3.36 | 4.08 | 4.93 | 6.00 | 7.46 | 9.71 |
| Efficiency | | | | | | | | | |
| | | | | | | | | | |
| 30°C | Capacity | 3038 | 3894 | 5414 | 7545 | 10235 | 13433 | 17086 | 21143 | 25552 |
| Power | 2027 | 2140 | 2375 | 2683 | 3012 | 3311 | 3527 | 3611 | 3511 |
| Current | 4.2 | 4.4 | 4.7 | 5.1 | 5.5 | 5.9 | 6.2 | 6.3 | 6.2 |
| MassFlow | 72.4 | 54.1 | 73.7 | 125.2 | 202.6 | 300.2 | 412.0 | 531.9 | 654.2 |
| COP | 1.50 | 1.82 | 2.28 | 2.81 | 3.40 | 4.06 | 4.84 | 5.86 | 7.28 |
| Efficiency | | | | | | | | | |
| | | | | | | | | | |
| 35°C | Capacity | 2650 | 3379 | 4725 | 6636 | 9059 | 11944 | 15239 | 18890 | 22848 |
| Power | 2048 | 2143 | 2381 | 2713 | 3086 | 3449 | 3750 | 3940 | 3966 |
| Current | 4.3 | 4.4 | 4.7 | 5.1 | 5.6 | 6.1 | 6.5 | 6.8 | 6.8 |
| MassFlow | 81.9 | 59.5 | 69.8 | 106.8 | 164.7 | 237.4 | 319.0 | 403.7 | 485.5 |
| COP | 1.29 | 1.58 | 1.98 | 2.45 | 2.94 | 3.46 | 4.06 | 4.79 | 5.76 |
| Efficiency | | | | | | | | | |
| | | | | | | | | | |
| 40°C | Capacity | 2416 | 3075 | 4305 | 6053 | 8268 | 10898 | 13891 | 17195 | 20758 |
| Power | 2125 | 2188 | 2415 | 2755 | 3157 | 3570 | 3943 | 4223 | 4361 |
| Current | 4.4 | 4.4 | 4.7 | 5.2 | 5.7 | 6.3 | 6.8 | 7.2 | 7.3 |
| MassFlow | 93.3 | 75.8 | 85.7 | 117.2 | 164.2 | 221.0 | 281.5 | 339.8 | 390.0 |
| COP | 1.14 | 1.41 | 1.78 | 2.20 | 2.62 | 3.05 | 3.52 | 4.07 | 4.76 |
| Efficiency | | | | | | | | | |
| | | | | | | | | | |
| 45°C | Capacity | 2176 | 2823 | 3994 | 5638 | 7702 | 10134 | 12883 | 15897 | 19123 |
| Power | 2266 | 2282 | 2483 | 2817 | 3234 | 3683 | 4111 | 4468 | 4703 |
| Current | 4.6 | 4.6 | 4.8 | 5.3 | 5.8 | 6.4 | 7.0 | 7.5 | 7.8 |
| MassFlow | 87.3 | 83.4 | 101.9 | 136.7 | 181.9 | 231.6 | 279.8 | 320.7 | 348.2 |
| COP | 0.96 | 1.24 | 1.61 | 2.00 | 2.38 | 2.75 | 3.13 | 3.56 | 4.07 |
| Efficiency | | | | | | | | | |
| | | | | | | | | | |
| 50°C | Capacity | | 2462 | 3632 | 5228 | 7199 | 9491 | 12054 | 14836 | 17783 |
| Power | | 2432 | 2591 | 2905 | 3323 | 3792 | 4262 | 4681 | 4998 |
| Current | | 4.8 | 5.0 | 5.4 | 5.9 | 6.6 | 7.2 | 7.8 | 8.2 |
| MassFlow | | 63.0 | 98.9 | 145.9 | 198.2 | 249.7 | 294.6 | 326.9 | 340.7 |
| COP | | 1.01 | 1.40 | 1.80 | 2.17 | 2.50 | 2.83 | 3.17 | 3.56 |
| Efficiency | | | | | | | | | |
| | | | | | | | | | |
| 55°C | Capacity | | | 3059 | 4666 | 6600 | 8811 | 11245 | 13851 | 16578 |
| Power | | | 2748 | 3027 | 3430 | 3905 | 4402 | 4868 | 5254 |
| Current | | | 5.2 | 5.5 | 6.1 | 6.7 | 7.4 | 8.0 | 8.5 |
| MassFlow | | | 57.3 | 125.4 | 193.6 | 255.9 | 306.3 | 338.9 | 347.8 |
| COP | | | 1.11 | 1.54 | 1.92 | 2.26 | 2.55 | 2.85 | 3.16 |
| Efficiency | | | | | | | | | |
| | | | | | | | | | |
| 60°C | Capacity | | | | 3789 | 5745 | 7931 | 10295 | 12784 | 15347 |
| Power | | | | 3188 | 3562 | 4029 | 4537 | 5037 | 5476 |
| Current | | | | 5.8 | 6.3 | 6.9 | 7.6 | 8.3 | 8.9 |
| MassFlow | | | | 55.7 | 148.7 | 230.6 | 295.5 | 337.4 | 350.3 |
| COP | | | | 1.19 | 1.61 | 1.97 | 2.27 | 2.54 | 2.80 |
| Efficiency | | | | | | | | | |
| | | | | | | | | | |
| 65°C | Capacity | | | | | 4474 | 6693 | 9043 | 11473 | 13930 |
| Power | | | | | 3725 | 4169 | 4676 | 5193 | 5671 |
| Current | | | | | 6.5 | 7.1 | 7.8 | 8.5 | 9.1 |
| MassFlow | | | | | 44.1 | 154.5 | 242.7 | 302.7 | 328.7 |
| COP | | | | | 1.20 | 1.61 | 1.93 | 2.21 | 2.46 |

Герметичный поршневой компрессор Bristol H23A623DBEA