Description | | -30°C | -25°C | -20°C | -15°C | -10°C | -5°C | 0°C | +5°C |
---|
25°C | Capacity | 2990 | 3997 | 5448 | 7340 | 9668 | 12429 | 15622 | 19242 | 23286 |
| Power | 1755 | 1907 | 2088 | 2269 | 2424 | 2524 | 2542 | 2449 | 2218 |
| Current | 3.6 | 3.8 | 4.0 | 4.2 | 4.4 | 4.6 | 4.6 | 4.5 | 4.3 |
| MassFlow | 63.5 | 82.8 | 111.1 | 148.2 | 193.7 | 247.5 | 309.3 | 378.8 | 455.8 |
| COP | 1.70 | 2.10 | 2.61 | 3.23 | 3.99 | 4.92 | 6.15 | 7.86 | 10.50 |
| Efficiency | | | | | | | | | |
| | | | | | | | | | |
30°C | Capacity | 2519 | 3430 | 4767 | 6528 | 8708 | 11306 | 14317 | 17738 | 21567 |
| Power | 1743 | 1913 | 2132 | 2374 | 2610 | 2812 | 2952 | 3004 | 2938 |
| Current | 3.6 | 3.8 | 4.1 | 4.4 | 4.7 | 5.0 | 5.2 | 5.3 | 5.2 |
| MassFlow | 53.0 | 70.6 | 96.9 | 131.5 | 174.1 | 224.6 | 282.6 | 348.0 | 420.3 |
| COP | 1.45 | 1.79 | 2.24 | 2.75 | 3.34 | 4.02 | 4.85 | 5.91 | 7.34 |
| Efficiency | | | | | | | | | |
| | | | | | | | | | |
35°C | Capacity | 2187 | 3007 | 4236 | 5871 | 7909 | 10348 | 13182 | 16411 | 20030 |
| Power | 1742 | 1909 | 2147 | 2427 | 2722 | 3005 | 3248 | 3422 | 3501 |
| Current | 3.6 | 3.8 | 4.1 | 4.5 | 4.9 | 5.3 | 5.6 | 5.8 | 6.0 |
| MassFlow | 46.8 | 63.4 | 88.2 | 120.9 | 161.3 | 209.0 | 263.8 | 325.6 | 393.9 |
| COP | 1.26 | 1.57 | 1.97 | 2.42 | 2.91 | 3.44 | 4.06 | 4.80 | 5.72 |
| Efficiency | | | | | | | | | |
| | | | | | | | | | |
40°C | Capacity | 1957 | 2691 | 3817 | 5332 | 7234 | 9519 | 12183 | 15224 | 18638 |
| Power | 1781 | 1924 | 2158 | 2456 | 2790 | 3133 | 3456 | 3732 | 3933 |
| Current | 3.6 | 3.8 | 4.1 | 4.5 | 4.9 | 5.4 | 5.9 | 6.2 | 6.5 |
| MassFlow | 43.0 | 59.2 | 83.1 | 114.5 | 153.1 | 198.7 | 250.9 | 309.7 | 374.5 |
| COP | 1.10 | 1.40 | 1.77 | 2.17 | 2.59 | 3.04 | 3.53 | 4.08 | 4.74 |
| Efficiency | | | | | | | | | |
| | | | | | | | | | |
45°C | Capacity | 1791 | 2445 | 3474 | 4875 | 6645 | 8782 | 11281 | 14140 | 17355 |
| Power | 1887 | 1984 | 2193 | 2488 | 2840 | 3221 | 3604 | 3960 | 4263 |
| Current | 3.8 | 3.9 | 4.1 | 4.5 | 5.0 | 5.5 | 6.0 | 6.5 | 7.0 |
| MassFlow | 39.6 | 55.9 | 79.5 | 110.2 | 147.6 | 191.6 | 241.9 | 298.2 | 360.2 |
| COP | 0.95 | 1.23 | 1.58 | 1.96 | 2.34 | 2.73 | 3.13 | 3.57 | 4.07 |
| Efficiency | | | | | | | | | |
| | | | | | | | | | |
50°C | Capacity | | | 3169 | 4462 | 6107 | 8100 | 10440 | 13122 | 16144 |
| Power | | | 2280 | 2550 | 2899 | 3297 | 3719 | 4135 | 4518 |
| Current | | | 4.3 | 4.6 | 5.1 | 5.6 | 6.2 | 6.8 | 7.3 |
| MassFlow | | | 75.4 | 105.9 | 142.8 | 185.8 | 234.6 | 289.1 | 348.8 |
| COP | | | 1.39 | 1.75 | 2.11 | 2.46 | 2.81 | 3.17 | 3.57 |
| Efficiency | | | | | | | | | |
| | | | | | | | | | |
55°C | Capacity | | | | | 5581 | 7438 | 9623 | 12134 | 14968 |
| Power | | | | | 2994 | 3389 | 3828 | 4283 | 4726 |
| Current | | | | | 5.2 | 5.7 | 6.3 | 7.0 | 7.6 |
| MassFlow | | | | | 136.6 | 179.2 | 227.2 | 280.3 | 338.4 |
| COP | | | | | 1.86 | 2.19 | 2.51 | 2.83 | 3.17 |
| Efficiency | | | | | | | | | |
| | | | | | | | | | |
60°C | Capacity | | | | | | | 8793 | 11139 | 13790 |
| Power | | | | | | | 3960 | 4432 | 4913 |
| Current | | | | | | | 6.5 | 7.2 | 7.8 |
| MassFlow | | | | | | | 217.5 | 269.9 | 326.8 |
| COP | | | | | | | 2.22 | 2.51 | 2.81 |
| Efficiency | | | | | | | | | |
| | | | | | | | | | |
65°C | Capacity | | | | | | | 7915 | 10100 | 12574 |
| Power | | | | | | | 4141 | 4609 | 5107 |
| Current | | | | | | | 6.8 | 7.4 | 8.1 |
| MassFlow | | | | | | | 203.5 | 255.8 | 312.2 |
| COP | | | | | | | 1.91 | 2.19 | 2.46 |
Герметичный поршневой компрессор Bristol H23A543DBEA
[contact-form-7 404 "Not Found"]