Производители
Описание
Description | | -30°C | -25°C | -20°C | -15°C | -10°C | -5°C | 0°C | +5°C |
---|
25°C | Capacity | 13378 | 18649 | 25515 | 33998 | 44117 | 55894 | 69350 | 84506 | 101382 |
| Power | 7984 | 9033 | 10114 | 11174 | 12156 | 13006 | 13668 | 14086 | 14206 |
| Current | 25.3 | 25.8 | 26.4 | 27.0 | 27.7 | 28.4 | 29.0 | 29.5 | 29.8 |
| MassFlow | 266.8 | 369.8 | 501.0 | 660.2 | 846.9 | 1061.0 | 1302.1 | 1570.0 | 1864.3 |
| COP | 1.68 | 2.06 | 2.52 | 3.04 | 3.63 | 4.30 | 5.07 | 6.00 | 7.14 |
| Efficiency | | | | | | | | | |
| | | | | | | | | | |
30°C | Capacity | | | 22556 | 30488 | 40038 | 51226 | 64073 | 78601 | 94830 |
| Power | | | 10257 | 11424 | 12536 | 13538 | 14375 | 14992 | 15333 |
| Current | | | 26.6 | 27.4 | 28.3 | 29.1 | 29.9 | 30.6 | 31.2 |
| MassFlow | | | 455.8 | 608.7 | 789.9 | 999.2 | 1236.4 | 1501.0 | 1792.9 |
| COP | | | 2.20 | 2.67 | 3.19 | 3.78 | 4.46 | 5.24 | 6.18 |
| Efficiency | | | | | | | | | |
| | | | | | | | | | |
35°C | Capacity | | | | 27414 | 36376 | 46958 | 59180 | 73062 | 88626 |
| Power | | | | 11726 | 12969 | 14126 | 15140 | 15957 | 16521 |
| Current | | | | 27.8 | 28.8 | 29.8 | 30.8 | 31.7 | 32.5 |
| MassFlow | | | | 566.2 | 741.6 | 945.8 | 1178.6 | 1439.7 | 1728.7 |
| COP | | | | 2.34 | 2.80 | 3.32 | 3.91 | 4.58 | 5.36 |
| Efficiency | | | | | | | | | |
| | | | | | | | | | |
40°C | Capacity | | | | | 33029 | 42986 | 54565 | 67785 | 82667 |
| Power | | | | | 13418 | 14731 | 15924 | 16943 | 17731 |
| Current | | | | | 29.3 | 30.5 | 31.7 | 32.9 | 33.9 |
| MassFlow | | | | | 698.7 | 897.5 | 1125.6 | 1382.8 | 1668.6 |
| COP | | | | | 2.46 | 2.92 | 3.43 | 4.00 | 4.66 |
| Efficiency | | | | | | | | | |
| | | | | | | | | | |
45°C | Capacity | | | | | | | 50124 | 62663 | 76846 |
| Power | | | | | | | 16688 | 17910 | 18924 |
| Current | | | | | | | 32.6 | 33.9 | 35.2 |
| MassFlow | | | | | | | 1074.2 | 1327.1 | 1609.5 |
| COP | | | | | | | 3.00 | 3.50 | 4.06 |
| Efficiency | | | | | | | | | |
| | | | | | | | | | |
50°C | Capacity | | | | | | | | 57594 | 71060 |
| Power | | | | | | | | 18820 | 20062 |
| Current | | | | | | | | 34.9 | 36.4 |
| MassFlow | | | | | | | | 1269.4 | 1547.9 |
| COP | | | | | | | | 3.06 | 3.54 |
Герметичный поршневой компрессор Bristol H2NG244DREF
[contact-form-7 404 "Not Found"]