R407C
| Tº | -20 | -15 | -10 | -5 | 0 | 5 | 10 | |||||||
| Tc | Qo | Pe | Qo | Pe | Qo | Pe | Qo | Pe | Qo | Pe | Qo | Pe | Qo | Pe |
| 40 | – | – | – | – | – | – | 46232 | 16419 | 59132 | 18107 | 75669 | 19818 | 96743 | 21617 |
| 45 | – | – | – | – | – | – | 42018 | 16943 | 53417 | 18818 | 67826 | 20655 | 86146 | 22518 |
| 55 | – | – | – | – | – | – | 34102 | 17428 | 43903 | 19889 | 55462 | 22189 | 69677 | 24393 |
R404A
| Tº | -20 | -15 | -10 | -5 | 0 | 5 | 10 | |||||||
| Tc | Qo | Pe | Qo | Pe | Qo | Pe | Qo | Pe | Qo | Pe | Qo | Pe | Qo | Pe |
| 40 | – | – | – | – | – | – | 51780 | 19374 | 65045 | 21004 | 81723 | 22791 | 102548 | 24643 |
| 45 | – | – | – | – | – | – | 47060 | 19993 | 58759 | 21829 | 73252 | 23753 | 91315 | 25671 |
| 55 | – | – | – | – | – | – | 38194 | 20565 | 48293 | 23071 | 59899 | 25517 | 73858 | 27808 |
R134A
| Tº | -20 | -15 | -10 | -5 | 0 | 5 | 10 | |||||||
| Tc | Qo | Pe | Qo | Pe | Qo | Pe | Qo | Pe | Qo | Pe | Qo | Pe | Qo | Pe |
| 40 | – | – | – | – | – | – | 30051 | 10672,4 | 38435,8 | 11769,6 | 49184,85 | 12881,7 | 62882,95 | 14051 |
| 45 | – | – | – | – | – | – | 27312 | 11013 | 34721,1 | 12231,7 | 44086,9 | 13425,75 | 55994,9 | 14637 |
| 55 | – | – | – | – | – | – | 22166 | 11328,2 | 28537 | 12927,9 | 36050,3 | 14422,85 | 45290,05 | 15855 |